Prosonic Flow 92 4 Wiring
Endress+Hauser 27
4Wiring
4.1 Connecting the sensor connecting cable
4.1.1 Connecting Prosonic Flow W, P, U sensors
Fig. 22: Connection of the flow sensors of the measuring system
A = View A
1 = Upstream sensor cable
2 = Downstream sensor cable
4.1.2 Cable specifications
Sensor cable
Special type coaxial cable.
Use the ready-to-use cables supplied by E+H with each sensor pair.
The cables are available in lengths of 5 m and 10 m.
The W, U sensors are connected by means of the BNC-connector plugs (IP 54).
"
Caution!
See special notes in Section 4.4 “Degree of protection” on Page 33.
Operation in zones of severe electrical interference:
The measuring device complies with the EMC requirements in accordance with
EN 61326/A1.