Prosonic Flow 92 4 Wiring
Endress+Hauser 31
Data logging specifications
Communication system: Half-duplex
Synchronising system: Start-stop synchronising
Transmission speed: 300 / 600 / 1200 / 2400 / 4800 / 9600 bps (selectable)
Parity: Even/odd number / none (selectable)
Data length: 8 bits
Stop bit: 1 bit / 2 bits (selectable)
Data code: ASCII
Isolation: Non-isolation between transmission line and transmitter.
!
Note!
After setup, make the following settings:
Transmission speed
–Parity
Stop bit
Communication control
Transmission of data with Prosonic Flow 92 is made following a request command
from the host computer.
When a command is received from the host computer, the data corresponding to the
command are transmitted from Prosonic Flow 92 to the host computer.
Commands with ASCII code are transmitted from the host computer to
Prosonic Flow 92.
The last code of each command is carriage return (0DH).