EasyManua.ls Logo

Endress+Hauser Prosonic S FMU90 - 4.3 Sensor connection

Endress+Hauser Prosonic S FMU90
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring
24
4.3 Sensor connection
4.3.1 Connection diagram
L00-FDU9xxxx-04-00-00-xx-002
(A): without sensor heater;
(B): with sensor heater;
(C): grounding at the terminal box;
(D): grounding at the transmitter FMU90;
(1): Screen of the sensor cable;
(2): Terminal box;
(3): Screen of the extension cable;
Colours of the strands: YE = yellow; BK = black; RD = red; BU = blue; BN = brown; GNYE = green-yellow
YE
9
(12)
BK
10
(13)
RD
11
(14)
FDU91/92
(FDU80/80F/81/81F/82)
BK
YE
RD
(1)
YE
9
(12)
BK
10
(13)
RD
11
(14)
FDU91F/93/95/96
(FDU83/84/85/86)
BK
YE
RD
GNYE
(2)
(3)
FMU90
(1)
(2)
(3)
FMU90
YE
9
(12)
BK
10
(13)
RD
11
(14)
FDU91
(FDU80/81)
BK
YE
RD
(1)
(2)
(3)
FMU90
BN BU
24 VDC
+
-
(A) (B)
(C)
max.
300 m
YE
9
(12)
BK
10
(13)
RD
11
(14)
FDU91F/93/95/96
(FDU83/84/85/86)
BK
YE
RD
GNYE
(1)
FMU90
(D)
max.
30 m
max.
300 m
max.
30 m
FDU91/92
(FDU80/80F/81/81F/82)
FDU91F/93/95/96
(FDU83/84/85/86)

Table of Contents

Other manuals for Endress+Hauser Prosonic S FMU90