How to adjust faulty calibration flow 01 or 02 on Endress+Hauser Measuring Instruments?
- KKara WilsonAug 26, 2025
To adjust a faulty calibration flow 01 or 02, adjust the calibration in the "flow" menu.
How to adjust faulty calibration flow 01 or 02 on Endress+Hauser Measuring Instruments?
To adjust a faulty calibration flow 01 or 02, adjust the calibration in the "flow" menu.
How to fix faulty calibration flow 01 or 02 on Endress+Hauser Prosonic S FMU90?
To correct a faulty calibration flow 01 or 02 on your Endress+Hauser Measuring Instruments, adjust the calibration in the "flow" menu.
Measurement Principle | Ultrasonic |
---|---|
Protection Class | IP68 |
Process Temperature | -40 to +80 °C |
Process Pressure | -1 to +3 bar |
Output Signal | 4-20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus |
Power Supply | 24 V DC |
Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
Housing Material | stainless steel |
Display | LCD |
Explains the intended purpose and applications of the Prosonic S FMU90 transmitter.
Details requirements for safe installation, commissioning, and operation, emphasizing specialist execution.
Covers safety for hazardous environments, installation in suitable areas, and compliance with regulations.
Explains safety symbols and conventions used in the manual for hazard identification and communication.
Identifies main components of the Prosonic S FMU90 in field and DIN-rail housing types.
Shows and explains the information present on the device's nameplate for identification.
Details product structure codes defining instrument versions, applications, housing, operation, and I/O options.
Lists items included in the standard delivery package for the Prosonic S FMU90.
Lists the various documents supplied with the instrument for user reference and operation.
Outlines the certifications and approvals obtained by the device, including CE marking and conformity.
Lists registered trademarks associated with the product and its technologies.
Outlines procedures for receiving, transporting, and storing the instrument to prevent damage.
Provides instructions and dimensions for mounting the Prosonic S FMU90 in its field housing.
Explains how to determine DIN-rail housing dimensions based on product structure and mounting on DIN rails.
Details the mounting of the remote display and operating module into a cabinet door or panel.
Directs users to specific technical information documents for sensor mounting procedures.
Lists checks to perform after installation to ensure correctness, proper protection, and secure mounting.
Describes accessing the terminal compartment in field and DIN-rail housings for wiring.
Provides detailed terminal assignments for basic and optional areas based on instrument version and product structure.
Illustrates connection diagrams for various Prosonic S sensors, including grounding and extension cables.
Details connecting the sensor heater supply voltage using a special terminal module.
Shows wiring diagrams for connecting external switches to the FMU90, specific to 'B' option models.
Provides connection diagrams and notes for FMT131 and Pt100 temperature sensors.
Explains how to shorten sensor cables, including precautions and shield handling.
Covers synchronization between multiple Prosonic S instruments and compatibility with other series.
Details connecting the separate display and operating module using a provided cable.
Explains potential equalization for sensors in field and DIN-rail housings, including grounding.
Lists checks to perform after wiring to ensure correct connections and operation.
Outlines methods for operating the Prosonic S: display module, PC tools, and HART terminal.
Details operating the device via its display module, including display elements and menu navigation.
Explains operation using PC-based tools like ToF Tool and FieldCare for device configuration.
Mentions operation via HART handheld terminal, noted as "in preparation".
Describes software, key combination, and hardware methods for locking/unlocking instrument configuration.
Explains how to reset the instrument to default settings and the implications for measurement.
Describes the Prosonic S structure, function blocks, and typical block configurations for applications.
Guides the user through the initial setup process after powering on the instrument for the first time.
Details steps for preparing the basic setup, including menu navigation and channel selection for calibration.
Provides an overview and detailed steps for the basic setup of level measurements, including sensor selection, calibration, and linearisation.
Details the "display" parameter, specifically the "type" setting for measured value display formats.
Explains parameters for selecting number format, decimals, separator character, and customized text display.
Covers the "back to home" parameter, specifying the return time to the measured value display.
Details configuring limit relays, including allocation, function, limit types, and switching points.
Guides on configuring alarm/diagnostic relays, including allocation of states and relay behavior.
Explains standard pump control principles, switch points, operating modes, and parametrization.
Details enhanced pump control principles, functions like limit simple/parallel, and parametrization.
Covers rake control configuration, detecting clogging via level difference or ratio, and switching parameters.
Explains allocating measured/calculated values to current outputs and displaying output current.
Details current span, mA value, output damping, and thresholds for current output configuration.
Covers HART communication settings like address, preambles, and short TAG for current output 1.
Details enabling and configuring current output simulation for testing purposes.
Covers system error signals, types of errors (Alarm, Warning), last error access, and error codes with remedies.
Lists common calibration errors related to measured values, filling/emptying, and echo loss with their remedies.
Explains using envelope curve display to check measurement signals, interference echoes, and scaling.
Lists software versions, changes, and corresponding documentation for the Prosonic S FMU90.
Provides guidance on safely cleaning the exterior of the instrument.
Outlines the repair concept, spare parts availability, and contact information for service.
Details specific procedures and requirements for repairing Ex-approved devices, emphasizing trained personnel.
Explains replacing the instrument or modules and downloading parameters using communication interfaces.
Guides on replacing a sensor and rechecking basic setup parameters like calibration and echo suppression.
Lists spare parts for field housing, DIN rail housing, PC boards, connectors, and cables with part numbers.
Outlines procedures for returning the transmitter for service, including decontamination and documentation.
Provides guidance on the proper disposal of instrument components based on material.
Directs users to contact information for Endress+Hauser representatives for support.
Describes the Commubox FXA191 HART for intrinsically safe communication via RS232C.
Describes the Commubox FXA195 HART for intrinsically safe communication via USB.
Describes the Commubox FXA291 for communication via service interface and USB.
Details the material, mounting, and order code for the protection cover for the field housing.
Lists specifications and order code for the mounting plate for the field housing.
Provides dimensions, material, and order codes for mounting brackets of different heights.
Describes the adaption plate for mounting remote displays and its compatibility.
Details the overvoltage protection unit for IP66 housing, including dimensions and order code.
Shows application examples and electrical connection diagrams for HAW56x overvoltage protection modules.
Lists available extension cables for sensors, including material, cable type, and order code.
Provides product structure details and cable length options for the FMT131 temperature sensor.
Provides a summary of key technical specifications including input sensors, output signals, power, performance, ambient conditions, and construction.
Details the "level" submenu, covering sensor selection, application parameters, calibration, linearisation, and distance mapping.
Explains safety settings parameters like output on alarm, echo loss, temperature alarms, and safety distance.
Covers configuration of limit relays, alarm/diagnostic relays, pump controls (standard/enhanced), and rake control functions.
Details output configuration, calculations, HART settings, and simulation options for current outputs.
Covers device properties such as units, tag marking, language, password/reset, and operating modes.
Explains accessing system information, including device details, error lists, sensor data, and operating hours.
Details display settings like format, units, value allocation, and back-to-home options.
Covers managing sensors, including their type, measurement parameters, and external inputs.
Shows default block configurations for different sensor input and output combinations as delivered.