60
IP1967EN - 2016-08-01
Display Description
RC - Loading configuration.
It is possible to load the congurations previously saved, or load the predened set-
tings available in the memory positions , , and . The predened set-
tings are as follows:
: OBBI
: FACIL
: LUXO
: ARC
Loading a predefined setting, standard average values are automatically set for certain
parameters (type of automation, operation speed, operation times and deceleration
times).
RL - Loading the last configuration set
CU - Viewing the electronic panels firmware version.
= Release 0.3.4 (example)
2 s
2 s
NOTE: the control panel automatically saves the last configuration set, and
keeps it memorised in the storage module. In the event of a fault or the re-
placement of the control panel, it is possible to restore the last configuration of
the automation by inserting the storage module and loading the last configura-
tion set.
i
i
Note: view only.
WARNING: it is possible that, owing to the type of automation and control panel, certain
menus are not available.