9.2.4.2. Set up a bond interface
1.
From the front panel menu, select System > System configuration > Network config
> Set up bond > Configure bond.
The following screen displays:
Bond interface config
will use the eth0
IPv4 and IPv6 config
if they are enabled
CANCEL NEXT
2.
Press the right-hand navigation button.
The following screen displays:
Bond interface config
Update parameter
mode: 802.3ad
BACK NEXT
3.
Set the mode field to the required option, either 802.3ad or active-backup.
4.
To accept, press the right-hand navigation button.
The following screen displays:
Bond interface config
Update parameter
miimon: 100
BACK NEXT
5.
Set the miimon field to the required value, the range is 0 - 10000 milliseconds.
Setting the miimon value to 0 disables it. This can prevent the bonding resilience from
functioning correctly in active-backup mode.
6.
To accept, press the right-hand navigation button.
The following screen displays:
nShield® Connect Installation Guide 36 of 73

Table of Contents

Other manuals for Entrust nShield Connect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Entrust nShield Connect and is the answer not in the manual?

Entrust nShield Connect Specifications

General IconGeneral
BrandEntrust
ModelnShield Connect
CategoryControl Unit
LanguageEnglish