Ethernet LEDs Status
Flashes regularly The status of the Ethernet link is currently
unknown (the Ethernet LEDs flash when
the module is powering up).
Off There is no Ethernet link. The Ethernet
cable is either not connected to the module
or the cable is not connected to a
functioning Ethernet device.
On, green only Indicates a 10Mb or 100Mb Ethernet link.
On, green and orange Indicates a 1Gb Ethernet link.
10.2. Module overheating
If the internal module of the nShield Connect exceeds the safe operating temperature,
the unit stops operating and displays the SOST error message on the Status LED. See
Status LED for details of the SOST error message.
10.3. Log messages for the module
To view log messages from the main menu of the module:
1.
Select System > System information
2.
Select either:
View system log
View hardserver log
The client can store logs, and can configure them to contain different types of message.
10.3.1. Information
This type of message indicates routine events:
nFast Server service: about to start
nFast Server service version starting
nFast server: Information: New client clientid connected
nFast server: Information: New client clientid connected - privileged
nFast server: Information: Client clientid disconnected
nFast Server service stopping
nShield® Connect Installation Guide 60 of 73

Table of Contents

Other manuals for Entrust nShield Connect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Entrust nShield Connect and is the answer not in the manual?

Entrust nShield Connect Specifications

General IconGeneral
BrandEntrust
ModelnShield Connect
CategoryControl Unit
LanguageEnglish