Initial Installation
QUALIFIED INSTALLERS ONLY
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a DirectVent Pro starting
collar in conjunction with EXCELDirect venting systems. Use of this system with the DirectVent Pro starting
collar is deemed acceptable and does not affect the Intertek listing of the appliance.
Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).
DirectVent Pro EXCELDirect Description
46DVA-06 DL6 6” Pipe Length
46DVA-09 DL9 9” Pipe Length
46DVA-12 DL1 12” Pipe Length
46DVA-18 18” Pipe Length
46DVA-24 DL2 24” Pipe Length
46DVA-36 DL3 36” Pipe Length
46DVA-48 DL4 48” Pipe Length
46DVA-60 60” Pipe Length
DLA30 16 1/2” - 29”, Adjustable
46DVA-24TA 17” - 24”, Adjustable
46DVA-E45 4DE45 45° elbow
46DVA-E90 4DE90 90° elbow
46DVA-VSS VSS Vinyl siding standoff/sheild
46DVA-WT 4WT Wall thimble
46DVA-SC SC Storm collar
46DVA-WFS 4CS Fire stop
46DVA-WS WS Wall strap/support/band
46DVA-F6 4FA Flashing, 0/12 to 7/12 roof pitch
46DVA-F7 4FB Flashing, 8/12 to 12/12 roof pitch
46DVA-FF 4F Flat ashing
46DVA-VCH SVT High wind vertical termination
46DVA-HC HT High wind horizontal termination
46DVA-KHC 4HTK Horizontal termination kit
The Berkeley replace has been tested and certied for use with M&G DuraVent DirectVent Pro and ICC
EXCELDirect venting systems. Refer to the table below for part numbers of commonly used parts for both
venting systems. For more venting parts please visit the respective manufacturers’ website.
WARNING: Do not mix parts from different vent manufacturers’ systems.
appRoveD venting paRts:
Table 3: Approved Vent Manufacturers
Manufacturer Trade Name Nominal Sizes
ICC EXCELDirect 4” - 6 5/8”
M&G DuraVent DirectVent Pro 4” - 6 5/8”