EOS Vision - Installation and Operating Instructions EN-15
Installation
Installation
This chapter describes how to install Vision. Prior to installing the unit, air
inlets and outlets must be installed in the cabin. It may be necessary to
mount additional fans in the inlets/outlets. All protective films must be
removed.
NOTICE
Damage due to incorrect mounting location
The heater is not suitable for outdoor use.
The heater must be operated only inside buildings and may not
be exposed to environmental conditions such as extreme hu-
midity and moisture or the possible formation of condensation
or corrosive substances in the ambient air, as well as other
weather conditions.
The heater is not designed to be installed or set up in an alcove
or under a bench or sloping roof.
3.1 Specifications for the cabin
The cabin must be planned and installed according to specifications before
the heater is installed. It must be ensured that the heater can be removed
from the cabin even after the cabin has been installed
All electrical installations laid inside the cabin must be suitable for silicone
cables and a temperature of at least 170°C.
All lines must be routed in such a way that they are well-protected, e.g. in a
cable duct. EOS recommends laying all connecting cables through a bend-
able metal tube connected to the protective conductor.
The floor on which the heater stands must be level.
In general, it should be noted that the sauna heater must not be set on a
floor made of highly flammable material (laminate, flooring made of plastic
material, etc.). Ceramic tiles are recommended as a flooring option.