EOS Vision - Installation and Operating Instructions EN-35
Electrical installation
4.3 Establishing an electrical connection
The connecting cable is pre-mounted on the sauna heater.
The heater is connected to the control unit or to the power extension unit
and the control unit via a connecting cable. Observe the regulations of the
local power supply company (EVU) and the Association for Electrical, Elec-
tronic & Information Technologies (VDE).
Connect the connecting cable to the control unit or to the power exten-
sion unit and control unit according to the connection diagrams.
4.4 Heating period limitation
All sauna heaters, except for those installed in public saunas, and which
must be operated under the supervision of personnel, must be equipped
with a timer that complies with IEC and EN standards. For safety reasons,
this timer limits the operation time. This timer is typically integrated in all
EOS sauna control units.
The operation time of a public sauna must be limited so that the heat-
ing elements are without power for a minimum of 6 consecutive hours
within a 24-hour period before an independent restart can take place.
Units used in private saunas must be limited to an operating time of
6 hours, and an automatic restart is not permitted.