EOS Vision - Installation and Operating Instructions EN-33
Electrical installation
WARNING
Risk of fire due to improper mounting
The control unit and the sauna heater must be suitable for connec-
tion to 230 V 1N ~.
Use suitable fuses and cable lines.
All line cross-section specifications are the minimum cross-sections for
copper lines.
4.2.3 Internal wiring
9 and 10 kW heater output
Internal wiring 9 and 10 kW
9 kW = 6x 1500 W
10 kW = 6x 1666 W
Rated output per DIN: 9 kW
Fuse protection – control unit 3 x 16 A
Connection mains 3 x 6 mm²
Connection control unit – sauna heater 3 x 1.5 mm²
Connection N terminal for sauna heater – mains 3 x 2.5 mm²
Connection PE terminal for sauna heater – mains ≥ 6 mm²
UVW
ZYEPX
NN)rG(N