EN-22 Installation and Operating Instructions - EOS Vision
Installation
EN
3.4 Connecting cable
The connecting cable is pre-mounted on the sauna heater and must be
routed through the base of the base plate.
The sauna heater must be connected to the control unit or control unit and
relay box by means of one or two connecting cables, depending on the
heater output. Install the cables in such a way that they are protected from
damage. To do this, route empty pipes from the installation site of the
sauna heater to the relay boxes.
Outside of the cabin, the cables must be routed under a suitable protective
cover (e.g. in a cable duct or empty conduits).
See the connection diagram: 4.2 Inner wiring diagrams, EN-28.
If there are no empty pipes in your cabin, drill a hole in the cabin wall
directly next to the sauna heater where the cable emerges from the sauna
heater, and guide the cable through this hole outward to the control unit
and relay box. The hole must be large enough to accommodate the cable.
The cable and all other connecting cables (supply line to mains and cabin
lighting) on the external side of the cabin must be protected from damage.
To do this, use installation pipes or attach a suitable protective cover.
If the electrical connection must be changed (e.g. when connecting to
230 V 1N ~), the following step is required:
Changing the connecting cable (optional), EN-24
Laying the connecting cable
1 Route the connecting cable through the base of the base plate.