19
CAN - CANopen Interface
Installation guide
a. Object 0x6113: Input actual value
This object provides the actual values of low voltage side.
Index
6113h
Name
Input actual values
Object code
RECORD
Sub Index
01h
Description
Voltage
Access
R/O
PDO mapping
No
Value range
SIGNED 32
Unit
V
Scaling
1 mV/u
Default value
0
Sub Index
02h
Description
Current
Access
R/O
PDO mapping
No
Value range
SIGNED 32
Unit
A
Scaling
1 mA/u
Default value
0
Sub Index
03h
Description
Power
Access
R/O
PDO mapping
No
Value range
SIGNED 32
Unit
W
Scaling
1 W/u
Default value
0