EasyManua.ls Logo

epic power CAN - 9 Examples of Application; Typical Application

epic power CAN
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
CAN - CANopen Interface
Installation guide
9. EXAMPLES OF APPLICATION
Typical application
START UP
AUTONOMOUS
MODE
SDO WRITE
0X6208 VALUE 0
SDO WRITE
0X6208 AT VALUE
1
SDO WRITE
0X6205:08 AT
CURRENT VALUE
(mA)
SDO WRITE
0X6205:0F AT
POWER VALUE
(W)
SDO WRITE
0X611B:01 AT
CURRENT VALUE
(mA)
TARGET CURRENT
HIGE SIDE
TARGET POWER
HIGE SIDE
TARGET CURRENT
LOW SIDE
NO YES
NMT START
NODE
(OPERATIONA)
SET MAXIMUM
AND MINIMUM
VOLTAGE OF
HIGH SIDE AND
LOW SIDE
SET MAXIMUM
AND MINIMUM
POWER
STOP DC/DC
EPC ENABLE
SDO WRITE
0x6200:02 AT
VALUE 0xFC
START DC/DC
SDO WRITE
0x6200:02 AT
VALUE 0xFD
YES
NO
NO
Fig. 11 Flowchart for typical application