27
CAN - CANopen Interface
Installation guide
f. Object 6204h: Output 1 actual values
This object provides the actual values of high voltage side.
Index
6204h
Name
Output 1 actual values
Object code
RECORD
Sub Index
01h
Description
Voltage
Access
R/O
PDO mapping
Yes
Value range
SIGNED 32
Unit
V
Scaling
1 mV/u
Default value
0
Sub Index
02h
Description
Current
Access
R/O
PDO mapping
Yes
Value range
SIGNED 32
Unit
A
Scaling
1 mA/u
Default value
0
Sub Index
03h
Description
Power
Access
R/O
PDO mapping
Yes
Value range
SIGNED 32
Unit
W
Scaling
1 W/u
Default value
0
g. Object 6205h: Output 1 set values
This object indicates the configured values of high voltage side.
Sub-index 02h: Maximum voltage.
Used with current control and power control.
If HVDC voltage goes above this value, EPC will stop and send an error.