SmartROC T35/T40 17 Compressed Air System
101 No: 7026962571.1.7027002891 en-US
17.3 Check Compressor Oil Level
Precondition
p
The machine is parked on a flat and level surface.
1.
Switch off the machine and allow the oil level to settle for at least 5 minutes.
2.
Check that the indicator on the gauge (A) is in the green zone.
3.
Fill with oil through inlet (B), if necessary. Use the correct amount and oil grade.
17.4 Drain Water Condensation from Compressor Tank
Precondition
p
The machine has been shut down for eight hours.
n
Open the drain plug below the machine and drain off the water.