Maintenance 8. Joint #4
L
S20-B Rev.4 129
(10)
Check if the Joint #
4 moves in a Jog motion by operating from EPSON RC+ menu
-
[Tools]
-[Robot Manager]-[Jog & Teach].
If the Manipulator oscillates with
MOTOR ON and the following errors are detected,
Error 5041: Motor torque output failure in low power state.
Error 4241: Over speed during low power mode was detected.
or when the joint other than Joint #
4
moves, the connector for other joint might be
connected to the Joint #
4 motor. Check the connector connection.
(11)
Execute the calibration of Joint #4.
F
or details, refer to Maintenance: 13. Calibration.