EPSON Stylus Photo 1390/1400/1410 Revision B
DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 102
15. Lift the Carriage Shaft to the hole of the Main Frame and remove the Spacer and
Left PG Cam from the Carriage Shaft.
Figure 4-72. Removing the Left PG Cam
16. Remove the Spacer and Right PG Cam from the Carriage Shaft.
Figure 4-73. Removing the Right PG Cam
17. Pull the Right CR Shaft Mounting Plate away from the tab on the Main Frame and
rotate toward you.
Figure 4-75. Rotating the Right CR Shaft Mounting Plate
Hole on Main
Frame
Spacer
PG Cam (Left)
Spacer
Right PG Cam
When installing the Right PG Cam, make sure that one of these
positions marked “0”, “+” or “++” comes to the bottom.
Figure 4-74. Right PG Cam Installation Direction