EPSON Stylus Photo 1390/1400/1410 Revision B
DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 124
4.2.8 Removing the Sensors
4.2.8.1 PE Sensor Holder
1. Remove the ASF Assy. See Section 4.2.4 on page 86.
2. Remove the PE Sensor Connector Cable from the five tabs on the Release Holder
Assy and the two tabs on the Head Cable Cover.
Figure 4-137. Releasing the Cables
3. Release the tabs that secure the PE Sensor Holder from the cutout of the Main
Frame with a flat-blade screwdriver, then slide it upwards then toward you to
remove it.
Figure 4-138. Removing the PE Sensor Holder
Tabs
PE Sensor Connector CableTabs
Release Holder Assy
Head Cable Cover
Front
Tab
PE Sensor Holder
Align the four tabs and Guide Pin on the PE Sensor Holder with the
positioning holes on the Main Frame correctly so that there is no
gap between the PE Sensor Holder and the Main Frame.
Figure 4-139. Installing the PE Sensor
Tabs
Guide pin