ADJUSTMENT Adjustment 143
11. With its conductor connection portion up, set the Adjustment Gauge in the
specified position (on the right side of the Front Paper Guide).
Setting Position
Rear direction: Match the rear end of the Gauge with the Driven Roller
Shaft of the Upper Paper Guide.
Right direction: Release the right end of the Gauge from the Tab on the
Front Paper Guide in Figure 5-10.
Figure 5-10. Setting the Adjustment Gauge
12. Move the Carriage Unit onto the Adjustment Gauge.
Moving position
Match the right end of the Gauge with the right end of the Carriage Unit.
Figure 5-11. Moving the Carriage Unit
13. Return the PG position to “--”.
14. As in Step 9, move the Parallelism Adjust Bushing on the right side of the frame to
set the right side PG position.
15. Set the PG position to 0 or above.
16. Set the Adjustment Gauge on the left side of the Front Paper Guide.
17. Move the Carriage Unit onto the left side Adjustment Gauge.
18. Return the PG position to “--”.
19. Check continuity again at the PG position on the left side. If the PG position is not
shifted, tighten the Parallelism Adjust Bushing with the screws to end the
adjustment. If it is out of position, repeat the adjustment procedure from Step 9.
Setting Position