EPSON Stylus Photo 1390/1400/1410 Revision B
DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 91
3. Disconnect all the FFCs and Connector Cables connected to the Board Assy in
order from the front, then draw out the Board Assy from the Printer taking care of
the interference between the Manual Paper Guide and the Radiation Plates on the
Board Assy.
CN2: USB Host (PictBridge) (not equipped for Stylus Photo 1390)
CN3: Relay Board FFC
CN5: Operation Panel FFC
CN6: Relay Connector Cable (for CR Motor)
CN7: PF Motor Connector Cable
CN8: Relay Connector Cable (for Pump Motor)
CN9: APG Motor Connector Cable
CN10: Head FFC
CN11: Head FFC
CN12: Head FFC
CN13: Relay Connector Cable (for ASF Motor)
CN14: CR Encoder Sensor/PW Sensor FFC
CN15: CSIC FFC
Figure 4-38. Removing the Board Assy
FFCs and Connectors
Interference
point
Board Assy
Manual Paper
Guide
Radiation Plates
Make sure that the FFCs are not crossing each other, and
connect the FFCs and Connector Cables to the Main Board
while paying attention to the edges of the Shield Plate.
Take care not to put the Board Assy onto the three Ground
Plates.
Figure 4-39. Installing the Board Assy (1)
When installing the FFC to the connector (CN15), secure it
with acetate tape as shown below.
Figure 4-40. Installing the Board Assy (2)
Grounding Plates
3mm
FFC
CN15
Acetate Tape