EPSON Stylus Photo R220/R230 Revision A
TROUBLESHOOTING Unit Level Troubleshooting 24
Table 1-11. Status and Possible Causes of Card Error
Error Status
LED Indication
STM3 Message
Occurrence
Timing
Carriage Unit
Position
at Power-on
Faulty Unit/Part Name Possible Causes Remedy
Card Error
Power : --
Paper : Fast Blink
Ink : --
Unknown error
Before start
to print
-
PW Sensor
The PW Sensor FFC is disconnected.
Refer to
Table 1-12
PW Sensor failure
The PW Sensor FFC is broken.
Main Board Elements failure
Table 1-12. Card Error Check Points by Phenomenon
Occurrence
Timing
Position of CR
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
Before start to
print
-
The top edge of the business card is not
fed to the PF Roller because the business
card is set in landscape orientation.
PW Sensor
1. Check if the PF Sensor FFC is not disconnected.
2. Check if the PW Sensor is not damaged.
3. Check if the PW Sensor FFC is not broken.
1. Connect the PW Sensor FFC to CN2 on the
CR Encoder Sensor Board.
2. Replace the PW Sensor with a new one.
3. Replace the PW Sensor with a new one.
Main Board 1. Check if any element on the Main Board is not damaged. 1. Replace the Main Board with a new one.
PW Sensor FFC