DISASSEMBLY / ASSEMBLY Disassembly 66
External View
Figure 2-27. Carriage Unit Removal (2)
CR Encoder Sensor Board Removal
1. Remove the screw which secures the CR Encoder Sensor Board to the
Carriage Unit with a No.0 screwdriver. Disconnect the CR Encoder FFC and
the PW Sensor FFC from the connector of the CR Encoder Sensor Board.
Then, remove the CR Encoder Sensor Board.
PW Sensor Board Removal
1. Release the three tabs which secure the Cap, PW Sensor and remove it.
2. Disconnect the PW Sensor FFC from the connector of PW Sensor Board.
Then, remove the PW Sensor Board.
PW Sensor Board
Connector
PW Sensor FFC
Tabs
Cap, PW Sensor
C.P.B. (P1) 1.7x5 (1.5-2.5kgf.cm)
Timing Belt
CR Encoder Sensor FFC
PW Sensor FFC
CR Encoder Sensor Board
C A U T I O N
Be careful not to damage the PW Sensor Board since it will be
non-secured state when removing the Cap, PW Sensor.