Setup & Operation 17. Fieldbus I/O
112 VT Rev.1
Fieldbus
I/O Module
Installation
(1)
Turn OFF the Manipulator.
(2)
Remove the optional slot cover on the back side of the Manipulator.
Sems bolt: 2-M3×6
Optional slot cover
(3)
Inset the fieldbus I/O module to the optional slot.
CAUTION
Check the tabs of the fieldbus I/O module are securely hooked on the board
when installing fieldbus I/O module. If tabs do not be hooked securely,
connecter or fieldbus I/O module may get damages.
(4)
Tighten screws by using special tool until fieldbus
I/O module is fixed completely.
Image of installation
Front
Back
Fieldbus
I/O Module
Removal
(1)
Unscrew the screws by using special tool until fieldbus I/O module is loosened.
(2)
Remove the fieldbus I/O module.
You can remove the module by pulling loosened screws toward.
(3)
Mount the optional slot cover.