Maintenance 18. Controller Unit
VT Rev.1 239
18.5 Replacing Cooling Fan
Name
Quantity
Note
Maintenance
parts
Cooling Fan 1 2191301
Tools
Cross-point screwdriver (No. 2)
1
Cooling Fan
Removal
(1)
Remove
the controller unit.
Reference: Maintenance 18.1 Replacing Controller Unit
(2)
Remove
the cooling fan.
Binding head screws: 4-M4×30
Cooling Fan
Cooling Fan
Installation
(
1)
M
ount a new cooling fan.
Binding head screws: 4-M4×30
Tightening torque: 0.45 ± 0.1N·m
(
2)
M
ount the controller unit.
Reference: Maintenance 18.1 Replacing Controller Unit