Page 14
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00 (33) 01 34 11 50 10
Web : www.ervor.com - Email : info@ervor.com
Manual G06
Edition: 10/2015 - rev A
5 - STORAGE
5 - A - UNDER 3 MONTHS
) A sealed package (eg. heat-sealed plastic) to avoid dust and surface damage.
5 - B - 1 YEAR MAXIMUM
) Drain compressor oil carefully.
) Dismount the 1st and 2nd stage cylinder heads.
) Clean cylinder heads and valves carefully.
) Inject storage oil into the cylinder heads and valves.
) Mount the cylinder heads.
) Fill the compressor with storage oil.
) Start the compressor and run for 10 min off load; introduce 20cl of oil into the compressor air
intake.
) A sealed package (long term) category 4C with dehydrating packs, conforming to
S.E.I. norms.
5 - C - OVER 1 YEAR and EACH SUCCESSIVE YEAR
) Drain storage oil carefully.
) Fill up with new storage oil.
) Start the compressor and run for 10min off load
) Start the compressor and run for 10min on load.
) A sealed package (long term) category 4C with dehydrating packs, conforming to
S.E.I. norms.
5 - D - STORAGE OIL
Storage oil (Can oil 25L ref. 7 550 035) : type ANTICORIT VCI UNI-0-40
Technical data :
- Density at 25°C : 0,9-0,97 g/ml
- Flash point : min 55°C
- Viscosity at 20°C : 250 mm2/s