11 - FAILURE ANALYSIS
11 - A - START UP FAILURE
11 - A - 1 - THE COMPRESSOR DOES NOT START
11 - B - RUNNING FAILURE
11 - B - 1 - THE COMPRESSOR STARTS BUT TRIPS
11 - B - 2 - THE COMPRESSOR RUNS BUT THERE IS NO DELIVERY PRESSURE
11 - B - 3 - THE COMPRESSOR OVERHEAT
Source of errors Solution
No power supply Check voltage
Coupling broken Replace
Piston jams Replace piston and fill with oil level
Source of errors Solution
Airing broken Replace decompression device
Loose cable Check the wiring
Source of errors Solution
Broken piston Replace
Broken output valve Replace
Source of errors Solution
Clogged non return valve Replace
Clogged output valve Replace
Worn piston rings Replace
No oil Fill with oil