9 - PREVENTATIVE MAINTENANCE
Working hours
9 - A - DAILY
) Drain the condensates from the air receiver.
) Drain check valve/separator using the manual drain valve.
(Not applicable in the case of automatic drain).
9 - B - EVERY 25 HOURS
) Check the oil level.
9 - C - AFTER THE FIRST 50 HOURS
) Drain oil and refill with fresh oil.
9 - D - EVERY 250 HOURS
) Replace the air intake filter.
9 - E - EVERY 500 HOURS OR EVERY YEAR
) Drain oil and refill with fresh oil.
) Check intake and compression valves.
9 - F - EVERY 1500 HOURS
) Replace intake and compression valves.
) Replace gaskets.
) Replace the air intake filter.
) Check the oil plug and the oil drain plug.
) Check the cooling coil assembly.
) Check the piston rings.
) Check the coupling.
) Check the cylinder heads.
) Drain oil and refill with fresh oil.