0-5574 5-3 SERVICE
PROBLEM CAUSE REMEDY
4 Electrode or cutting
tip installation error
A Electrode or tip is not installed
correctly.
A Reinstall the electrode or tip.
B Electrode or tip is seriously
worn.
B Replace worn electrode or tip.
C Plasma torch failure. C Have an accredited CIGWELD
service provider repair or replace.
D Power source component
failure.
D Have an accredited CIGWELD
service provider repair or replace.
5 Voltage error A The mains supply voltage out
of range.
A Check if the input voltage is within
204~276.
B Power source component
failure.
B Have an accredited CIGWELD
service provider repair or replace.
6 Over temperature
error
A Duty cycle of power source has
been exceeded.
A Leave the power source switched
ON and allow it to cool. Note that
Over Temperature Error screen
must be extinguished prior to
commencement of cutting.
B Air flow through or around the
unit is blocked.
B
Keeptheventilationclearance.
C Fan failure C Check if the fan is turnning when
the main switch is ON. Have an
accredited CIGWELD service
provider repair or replace if the fan
is not working.
D Power source component
failure.
D Have an accredited CIGWELD
service provider repair or replace.