TECHNICAL DATA
0463 714 001
- 35 -
© ESAB AB 2020
Rogue ES 180i Rogue ES 150i
Transportation temperature -20 to +55°C
(-4 to +131°F)
-20 to +55°C
(-4 to +131°F)
Continual sound pressure at
no-load
<70dB <70dB
Dimensions l×w×h 403×153×264mm
(15.8×6×10.4in.)
403×153×264mm
(15.8×6×10.4in.)
Weight 6.8kg 6.8kg
Insulation class transformer H H
Enclosure class IP23S IP23S
Application class
ES 180i Pro, ES 200i Pro
Technical data
Rogue ES 200i Pro Rogue ES 180i Pro
Outlet voltage 230V±15%
1~ 50/60Hz
115V±15%
1~ 50/60Hz
230V±15%
1~ 50/60Hz
115V±15%
1~ 50/60Hz
Primary current
I
max
MMA
30 A 29A 26A 29A
I
max
LiveTIG
19.5A 24A 16.5A 24A
No-load power
demand when in
energy saving
mode
50W 50W 50W 50W
Setting range
MMA 20-200A 20-110A 20-180A 20-110A
Live TIG 10-200A 10-140A 10-180A 10-140A
Permissible load at MMA
25% duty cycle 200A/ 28V 110A/ 24.4V 180A/ 27.2V 110A / 24.4V
60% duty cycle 129A/ 25.2V 70A/ 22.8V 116A/ 24.6V 70A/ 22.8V
100%dutycycle 100A/ 24V 55A/ 22.2V 90A/ 23.6V 55A / 22.2V
Permissible load at Live TIG
25% duty cycle 200A/ 18V 140A/ 15.6V 180A/ 17.2V 140A / 15.6V
60% duty cycle 129A/ 15.2V 90A/13.6 V 116A/ 14.6V 90A / 13.6V
100% duty cycle 100A/ 14V 70A/12.8 V 90A/ 13.6V 70A / 12.8V
Apparent
powerI
2
at
maximum
current
6.9kVA 3.3kVA 6kVA 3.3kVA
Active powerI
2
at maximum
current
6.8kW 3.26kW 5.94kW 3.26kW