TECHNICAL DATA
0463 714 001
- 40 -
© ESAB AB 2020
Rogue ET 200iP
Insulation class transformer H
Enclosure class IP23S
Application class
ET 200iP Pro
Technical data
Rogue ET 200iP Pro
Outlet voltage 230V±15%
1~ 50/60Hz
115V±15%
1~ 50/60Hz
Primary current
I
max
MMA
30A 29A
I
max
LiveTIG
19.5A 24A
No-loadpowerdemand when in
energy-saving mode 50W 50W
Setting range
MMA 20-200A 20-110A
Live TIG 10-200A 10-140A
Permissible load at MMA
25% duty cycle 200A/ 28V 110A/24.4V
60% duty cycle 129A/ 25.2V 70A/ 22.8V
100% duty cycle 100A/ 24V 55A/ 22.2V
Permissible load at Live TIG
25% duty cycle 200A/ 18V 140A/ 15.6V
60% duty cycle 129A/ 15.2V 90A/ 13.6V
100% duty cycle 100A/ 14V 70A/ 12.8 V
Apparent power I
2
at maximum current
6.9kVA 3.3kVA
Active power I
2
at maximum current
6.8kW 3.26kW
Power factor at maximum current
Live TIG 0.99 0.99
MMA 0.99 0.99
Efficiency at maximum current
MMA 82% 85%
Live TIG 82% 85%
Open-circuit voltage U
0
max
VRD 35 V deactivated 78V 78V
VRD 35 V activated <30V <30V
Operating temperature -10to +40°C
(+14to 104°F)
-10to+40°C
(+14to 104°F)