EasyManua.ls Logo

ESAB ES 150i - ET 200 iP Pro Electrical and Performance Specifications

ESAB ES 150i
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL DATA
0463 714 001
- 40 -
© ESAB AB 2020
Rogue ET 200iP
Insulation class transformer H
Enclosure class IP23S
Application class
ET 200iP Pro
Technical data
Rogue ET 200iP Pro
Outlet voltage 230V±15%
1~ 50/60Hz
115V±15%
1~ 50/60Hz
Primary current
I
max
MMA
30A 29A
I
max
LiveTIG
19.5A 24A
No-loadpowerdemand when in
energy-saving mode 50W 50W
Setting range
MMA 20-200A 20-110A
Live TIG 10-200A 10-140A
Permissible load at MMA
25% duty cycle 200A/ 28V 110A/24.4V
60% duty cycle 129A/ 25.2V 70A/ 22.8V
100% duty cycle 100A/ 24V 55A/ 22.2V
Permissible load at Live TIG
25% duty cycle 200A/ 18V 140A/ 15.6V
60% duty cycle 129A/ 15.2V 90A/ 13.6V
100% duty cycle 100A/ 14V 70A/ 12.8 V
Apparent power I
2
at maximum current
6.9kVA 3.3kVA
Active power I
2
at maximum current
6.8kW 3.26kW
Power factor at maximum current
Live TIG 0.99 0.99
MMA 0.99 0.99
Efficiency at maximum current
MMA 82% 85%
Live TIG 82% 85%
Open-circuit voltage U
0
max
VRD 35 V deactivated 78V 78V
VRD 35 V activated <30V <30V
Operating temperature -10to +40°C
(+14to 104°F)
-10to+40°C
(+14to 104°F)