8 ERROR CODES
0463 930 001
- 33 -
© ESAB AB 2023
Error code Description
Err 215 Output Short Circuit
Short circuit is detected during output activation fault trigger.
Action:
1. Make sure that the welding cables are properly installed of the weld
terminals.
2. Turn OFF the power source and wait a few minutes. If the error code
persist, retrieve the service log.
Err 216 Over output current
The output amps over design limitation.
Action:
1. Make sure that you are not exceeding the rated data for the power
source.
2. Turn OFF the power source and wait a few minutes.
3. Set the power source to the rated output voltage & current, If the error
code persist, retrieve the service log.
Err 311 Over output current for wire feeder
The wire feeder motor amps over design limitation.
Action:
1. Check the liner, clean using pressurized air. Replace the liner if
damaged or worn out.
2. Check the wire pressure setting and adjust if needed.
3. Check the drive rolls for wear and replace if needed.
4. Make sure the filler metal spool can rotate without much resistance.
Adjust the brake hub if needed.