8 ERROR CODES
0463 930 001
- 32 -
© ESAB AB 2023
8 ERROR CODES
The error code is used to indicate that a fault has occurred in the equipment. Errors are indicated by
the text "Err" followed by the error code number shown in the display.
Screens
8.1 Error code descriptions
Error codes that the user can handle are listed below. If any other error code appears, contact an
authorised ESAB service technician.
Error code Description
Err 002 Torch trigger-related error
The torch trigger be pressed all the time or the torch trigger signal be short circuit and
the ARC is also not established.
Action:
1. Check that the Torch Trigger Switch is not depressed when the Power
Source is switched ON.
2. When releasing the trigger, check if the torch switch is short circuit.
3. If the error code persist, retrieve the service log.
Err 205 Lack-phase protection
The input socket loses the phase when connecting the input wires to the socket.
Action:
1. Check the condition of the mains supply and make sure they are all
good connection.
2. Make sure that the power source connects to the rated input mains
supply voltage and turn the mains power supply switch ON. If the error
code persist, retrieve the service log.
Err 206 Over temperature
The power source run more than the duty cycle.
Action:
1. Wait until the power source cools down for ten minutes.
2. Make sure that you are not exceeding the rated data for the power
source.
3. Make sure that the power source connects to the rated input mains
supply voltage and turn the mains power supply switch ON. If the error
code persist, retrieve the service log.