F4 Pilot Flame and Burner Positioning
The pilot and burners are shown in the image below.
It is recommended to have a minimal gap (approximately 3 to 5 mm) between the spark electrode
and the flame rectification electrode, as shown in the image below. It is also crucial to ensure that the
flame rectification electrode is centred between the pilot shroud guards on either side.
F5 Weather Cover (Optional)
If desired, an optional weather cover can be purchased from your Escea retailer, which protects the
fuelbed and burners. This should only be placed while the fire is not in use.
To fit the weather cover, ensure that the fire is o and cooled. Place the front edge on the glass at
the front of the fire; the rear flange of the weather cover will rest on the burner supports behind the
rear burner. To remove the weather cover, lift it upwards and away from the fire.
Warning: The fire MUST NOT be operated while the cover is fitted.
Warning: The cover MUST NOT be fitted while the fire is hot. A cooling period of 30 minutes must
be observed before fitting.