B
ACDEFGSERVICE
27
G
Installation Checklist
Go through the following checklist to ensure you have installed the appliance correctly
□ Correctly sized cavity
□ Correct clearances to combustibles
□ An electrical isolating switch to the appliance, accessible after finished installation
□ Correctly sized gas supply with a pressure test point, ensuring adequate supply with all other
gas appliances in the dwelling running
□ Gas type conversion process carried out if required
□ A weather-tight 240V supply with the 240/24V transformer protected from the elements
□ The appliance fixed to the cavity
□ The appliance plugged into a mains electricity supply
□ All gas joints and pressure points leak tested with suitable leak detection solution and drop
tests completed on gas pipework
□ Fuel bed correctly installed
□ A fitted fascia
□ Operated the fire and verified that it lights reliably and safely
□ Data label marked up with correct gas type and dated by installer if converted during
installation
□ Home-owner shown how to operate the appliance correctly
□ Warranty card filled in with installer details and appliance serial number
□ User Guide made available for end user
□ Plumbing Industry Commission Compliance Certificate given to end user