8
B4 Cavity Base
This appliance MUST be fully supported on its base over the entire area of the
underside of the appliance. The base must also be level and strong enough to
support the total product weight.
The EF5000 has ventilation gaps behind the fascia at the top and bottom. These
MUST NOT be blocked. Ensure there is a gap of at least 30mm between the
bottom of the fascia and anything below.
B5 Wall Cladding
The temperature of the wall directly above the fire can reach high temperatures.
It may discolour paint finishes. It is recommended to check the manufacturer’s specifications for heat
resistance prior to installing any cladding.
Some dark coloured exhaust stains may also become visible directly above the fire due to the exhaust.
In most cases, this can be cleaned o with water and a brush.
B6 Clearance to Combustibles
The minimum clearance distance between a combustible ceiling and the fascia must be no less than
1400mm.
Warning: Under no circumstances should anything be closer than 1 meter in front of the EF5000,
including: people, pets, or furniture.
Warning: Do not install a TV above the fire under any circumstances.
CEILING
WALL
1400mm Minimum
30mm Minimum
1000mm
Minimum
SIDE VIEW
30mm
minimum
EF5000 Fascia
Ventilation gaps -
do not block
If a hearth is installed, a clearance of
30mm must be maintained between
the bottom of the fascia and anything
below.