This Manual contains descriptive, maintenance and spare parts information for the SES 2000 Vac (LS3) autoclave units only.
Separate installation and user instructions are given in the SES 2000 Vac (LS3) autoclave 'Instructions for Use', ST-IM62.
When replacing parts during maintenance procedures ONLY use parts supplied by Eschmann Equipment or the safety of the autoclave may be affected.
The autoclave is a portable steam unit heated by electric elements. For sterilization of porous loads, a vacuum is created in the chamber.
The following equipment, designed for control or protection, is incorporated in the autoclave:
The unit has five fuses, rated as shown in TECHNICAL DATA, connected to the mains supply and relay board.
Includes transformer, voltage regulators, and connections for mains, signals, and sensors.
Water fill, discharge, steam bleed, air in, and vacuum solenoid valves, plus filters and safety valve.
Details components like vacuum pump, condenser, filters, chamber and band heater sensors, and ports.
Describes the Control Board, Front Panel Board, Pressure Transducer, Printer, Fans, Band Heater, and EMC Board.
Describes the basic sequence of operation during a sterilization cycle, including power on, door status, and programme selection.
Lists and explains the various status messages that can appear on the autoclave's digital display during operation.
Details how error codes are displayed, managed, and investigated during an operating cycle.
Lists all error codes displayed by the autoclave, their meaning, and potential causes.
Details the location and types of fuses used in the autoclave for protection, as specified in the Technical Data.
Provides a systematic table of common faults, their possible causes, and recommended remedies.
Provides step-by-step procedures for removing, cleaning, and refitting various components of the autoclave.
Details removal, cleaning, and refitting steps for the Autoclave Cover and Reservoir Assembly.
Instructions for removing and refitting the transformer unit, including disconnection and reconnection of electrical connections.
Procedures for removing and replacing the Control Board, Pressure Door Lock, Steam Bleed Valve, and Door Interlock Microswitch.
Details the removal and replacement procedures for various solenoid valves, including precautions for dismantling.
Procedures for replacing Water-Fill Solenoid Valve, Heating Element, Door Seal, and Vacuum Pump.
Covers replacement of Condenser, Cooling Fans, Bacterial Filter, Discharge Line Filter, Pressure Transducer, and Solid-State Relay Board.
Details replacement procedures for EMC Board, Printer, Safety Valve, temperature sensors, power switch, float switch, cooling ducts, and band heater.
Procedures for replacing manual reset cut-out, reservoir water filter, and maintenance of the diaphragm vacuum pump.
Describes how to access and use special modes like Engineering Mode, Machine Set-Up Mode, and Set-Up Procedure.
Step-by-step guide for entering the autoclave's serial number, including prefix letters, modification state, year, month, and number.
Covers setting cycles, date, time, cycle counter, and serial number for the autoclave configuration.
Details error codes, clearing procedures, and the process for performing a leak test.
Instructions for calibrating the autoclave, including general notes, preparation, and the calibration procedure itself.
Details the procedure for testing the pressure relief valve, including safety precautions and operating steps.
Procedure for calibrating the band heater temperature to ensure correct drying cycle performance.
Describes how to perform a functional test using a specific sterilization cycle to verify autoclave operation.
Lists and illustrates general spare parts for the autoclave, with part numbers, descriptions, and quantities.
Illustrates and lists spare parts for pipes and valves, including solenoid valves, filters, and tubing.
Illustrates and lists spare parts related to the heating system and process control components.
Provides an overview of the autoclave printer's operation, output information, and cycle stage abbreviations.
Details procedures for renewing ribbon cartridges and setting printer date and time.
Details modifications to the PCA 424138 and Relay Assembly 112507, including replacement procedures and troubleshooting.
Provides instructions and parts for fitting new chokes to the EMC board, addressing chassis compatibility.