16
MENU SETUP
MENU MODE SIMPLE
YEAR 2013
MONTH 5
DAY 15
HOUR 5
MINUTE 55
MENU SETUP 1/2
MENU MODE EXPERT
METER TYPE pH
T SENSOR NONE
SET TEMPERATURE 25
CALIBRATION MENU TIMEOUT 05:00
DELAY AT STARTUP 00:05
AUX OUTPUT MODE OFF
YEAR 2013
MONTH 5
DAY 15
MENU SETUP
1/2
MENU MODE EXPERT
METER TYPE pH
T SENSOR NONE
SET TEMPERATURE 25
CALIBRATION MENU TIMEOUT 05:00
DELAY AT STARTUP 00:05
AUX OUTPUT MODE OFF
YEAR 2013
MONTH 5
DAY 15
7.4. PROGRAMMING MENU SETUP
7.4.1 MENU MODE
Starting from the MAIN SCREEN press OK key until enter in MENU MODE.
Than change SIMPLE to EXPERT by pressing + key or key.
Change SIMPLE in EXPERT
by press + or - key
Chose the parameter by press + or key.
Press
OK key to confirm the choice and set
the value for the parameter on right column.
Modify the value for the parameter by press + or
key. Press
OK
ke
y
to confirm the choice and return
on left column to set an other parameters.