14 Upgrading software
Upgrading remote interface devices
Crossed wiring ~ Sometimes when you’re using twisted pair wiring,
a remote interface device does not appear on the Remote Units list.
The cause could be crossed wiring. This problem is covered in the
Upgrade software section of the console user manual under Devices
missing from the list. To swap the wiring in the LPC, execute the
autocontrol for softkey S6 (M7 / (M2 and M5 and M6)).
Setting the configuration ~ You may be unable to communicate
with one or more ETCNet 2 remote interface devices because they
are configured for an ETCNet2 network. This problem is covered in
the Upgrade software section of the console user manual under
Devices missing from the Remote Units list. To set the network
configuration in all ETCNet2 remote interface devices to ETCNet,
execute the autocontrol for softkey S5 (M7 / (M1 and M5 and M6)).
Upgrade all units ~ To upgrade all remote interface devices at once,
execute the autocontrol for softkey S1 (M7 / (M1 and M6)).
Upgrade some units ~ To upgrade some units, follow the procedure
below:
1. Use the Plus or Minus autocontrols to move forward or backward
through the Remote Units list.
2. While highlighting a unit you wish to upgrade, execute the
autocontrol for softkey S8 (M7 / (M1 and M6)) to mark the unit.
3. Repeat step 2 to mark as many units as you wish.
4. After marking, execute the autocontrol for softkey S2 (M7 / (M2
and M6)) to upgrade the marked units.
Upgrade only one unit ~ Follow the procedure below:
1. Use the Plus or Minus autocontrols to move forward or backward
through the Remote Units list.
2. While highlighting the unit you wish to upgrade, execute the
autocontrol for softkey S3 (M7 / (M3 and M6)) to upgrade the unit.