A1 0 99 °C 70
evaporator temperature above which evaporator high
temperature alarm is activated (code AH”); see also
parameter A2
A2 0 1 - - - - 1
enabling of evaporator high temperature alarm (“AH” code)
1 = yes
Par. Min. Max. Unit Default Evaporator and condenser fan
F0 0 1 - - - - 0
evaporator fan activity during block phase
0 = operation in parallel with compressor
1 = continuous operation
F1 0 1 - - - - 0
evaporator fan activity during storage. cooling, pre-cooling
phase
0 = operation in parallel with compressor
1 = continuous operation
F2 0 1 - - - - 0
evaporator fan activity during recovery phase
0 = operation in parallel with main utilities
1 = continuous operation
F3 0 1 - - - - 0
evaporator fan activity during proving, heating phase
0 = operation in parallel with main utilities
1 = continuous operation
F4 0 1 - - - - 0
evaporator fan activity during baking delay phase
0 = operation in parallel with main utilities
1 = continuous operation
F10 0 100 % 100 fan speed in pre-cooling phase
F11 0 100 % 100 fan speed in dehumidification phase
F12 0 15 m 2 fan stop after dripping phase
F13 0 250 s 0
delayed switch-off of the evaporator fan from main utilities
off
F14 1 600 sec 0
evaporator fan cycle time, if set at 0, the cyclical switch-on
of the fan will be deactivated.
F15 1 600 sec 0 evaporator fan switch-on time within the cycle time F14
F16 0 99 °C 20
temperature of the condenser above which the condenser
fan is on also with compressor off
F17 0 240 s 5
condenser fan switch off delay on compressor switch off
(valid only with condenser probe disabled)
F18 0 240 s 15
evaporator fan switch-on delay from door closure, i.e. from
the deactivation of the door micro switch input
F19 0 100 % 20 minimum evaporator fan speed settable
F20
0 100 % 100 maximum evaporator fan speed settable
F21 0 100 % 75 evaporator fan top speed
F22 1 10 s 5 top speed at evaporator fan switch-on