93
Raw Water System
Open the seacock and check for leaks.
Start the generator and inspect the strainer
for leaks and proper water ow at the exhaust
port. If there is no discharge within thirty
seconds, shut down the generator and nd
and correct the problem.
Cleaning the Air Conditioner Strainer
Turn off the air conditioner and deactivate the
air conditioner circuit breaker on the cabin AC
panel.
Close the intake water ball valve at the raw
water manifold.
Turn the strainer bowl counterclockwise to
remove it and remove the screen.
Thoroughly ush the screen and the inside of
the strainer bowl to remove foreign matter.
Lubricate the seal.
Reassemble the strainer making sure that the
bowl is tight.
Open the seawater ball valve and check for
leaks.
Activate the air conditioner and monitor the
ow of water out of the air conditioner thru-
hull tting in the hull side. If no water is
owing after 30 seconds, shutdown the air
conditioner and nd and correct the problem.
Intake Scoop Strainer
A thru-hull water intake scoop and strainer pro-
vides seawater to the raw water manifold. This
strainer is located on the hull bottom and must be
kept free of mud, weeds and other debris.
The strainer should be visually inspected each
time the boat is hauled for accumulation of ma-
rine growth, weeds and other foreign objects. If
clogged or dirty, the strainer should be cleaned.
HVAC Pump Sea Strainer
Raw Water Manifold Speed Scope