THG/TLG/TLT
8.2 Maintenance plan
The sections below describe the maintenance work required
on the pillar to help provide optimal and smooth operation of
the device.
If increased wear or dirt is found during regular checks, the
required maintenance intervals should be shortened.
Contact the manufacturer in the event of inquiries regarding
maintenance work and intervals; see the service address on
the back cover page.
Interval Maintenance work To be carried out by
Daily
Cleandustanddirtothepillar
(refer to chapter ⮑ 8.3.1 Cleaning).
Operator
Check pillar for visible damage
(refer to chapter ⮑ 8.3.2 Visual check of condition).
Qualiedpersonnel
Monthly
Function check of operating features and safety equipment.
Check the attachment of the device to the upper and lower
attachment plates.
Qualiedpersonnel
Every 6 months
Checkthefunctionoftheemergencycut-oswitch,ifpresent.
Check all plugs to be sure they are properly inserted.
Qualiedelectrician
Operator
Denition
through the
processor
Conduct visual inspection of the condition of the permanent
safeguard and the routing of the supply and control cable within the
application. Cable routing elements should not be loose or broken.
Qualiedelectrician
NOTE
If the telescopic pillar is used outside of the specified
environmental conditions, check all components that are directly
exposed to these environmental conditions monthly for visual
changes (such as oxidation or sedimentation).
8.3 Maintenance work
Improper cleaning
NOTICE
Damage due to incorrect cleaning!
Incorrect cleaning may lead to significant material damage.
Therefore:
• Do not use any aggressive cleaning agents. Water used for clean-
ing, including the chemical additives, must be pH-neutral.
• Only use the auxiliary materials listed by the manufacturer.
• Do not treat emergency lowering mechanism for quick adjustment
system with oil, grease or other lubricants.
• No steam jets or pressure washers may be used for cleaning.
• Other cleaning agents or cleaning devices may only be utilized
with the manufacturer’s approval.