Rectifying faults
Error messages (power source)
099-5TLPXQ-EW501
29.01.2021
After switching on the automa-
ted system, no wire feeder was
detected
Check or connect control
cables of wire feeders; check
the identification number of
the automated wire feeder (for
1DV: number 1, for 2DV: each
a wire feeder with number 1
and a wire feeder with number
2)
Wire feeder 2 not detected
Check or connect the control
lines of the wire feeders
Open circuit voltage reduction
error
if necessary, disconnect ex-
ternal machine from the
welding circuit; inform Service
Overcurrent detection on wire
feeder
Do not place the liner in tight
radii; check wire core for
smooth movement
One phase of the mains voltage
has failed
Check mains connection,
mains plug and mains fuses
Wire feeder fault (slave drive)
Check connectors, cables,
connections
Permanent overload of the wire
drive (slave drive)
Do not place the liner in tight
radii; check wire core for
smooth movement
Check welding circuit for short
circuit
Check welding circuit; isolate
welding torch before deposi-
ting
A machine connected to the
system is not compatible
Please disconnect the incom-
patible machine from the sys-
tem
A machine's software is not
compatible.
The actual value of a welding
parameter is outside the spe-
cified tolerance field
Observe tolerance fields; ad-
just welding parameters
System component not found
[1]
factory setting
[2]
option
[3]
only machine series Titan
[4]
not machine series Titan