terminate playing the message, waiting for the caller to complete dialing;
5. The caller will be connected to Operator if he/she dial 0 first for inquiry;
3.5.5 Monitoring the recorded OGM (For CS+/TS+ Series)
Format: 13 M # ( M=1,2,3) ( the paragraph of the OGM )
Description: Confirms the recorded message in the OGM recording program, you can check if
the recording is satisfied or not, if not, you can record again.
3.5.6 One paragraph OGM Mode (For CS+/TS+ Series)
Format:: 1 2 0 0 #
Description: to recording one paragraph OGM(20s total)
Format:: 1 3 0 0 #
Description: to play and minitor one paragraph OGM(20s)
: 1. After performed above two commands(1200# or 1300#), system will change to one
paragraph OGM mode automatically.
2. After performed 12M#、13M# two commands, system will change to three
paragraphs OGM mode automatically.
3. The OGM mode will be kept after power off.
3.6 Process in Auto-attendant Mode
3.6.1 No Dial Process
Format: 1 6 0 #
Description: In auto-attendant mode, if the C.O. line doesn't dial the extension number over 5
seconds or more after hearing the OGM, then the C.O. line will be hung up.
Default setting: The C.O. line will be hung up if no dialing.
Format: 1 6 1 # or 1610#
Description: In auto-attendant mode, if the C.O. line doesn't dial the extension number over 5
seconds or more after hearing the OGM(no dialing in The DISA), then the C.O. line
will be transferred to Operator.
Format: 1 6 1 6 #
Description: The system will call the operator mode Ringing Extensions.(setting refer to
3.8.2&3.8.3)
3.6.2 Called Extension Busy Process
Format: 165#