ALARMS
27
ENGLISH
ALARMS17.
DISPLAY EXPLANATION SOLUTION
Indicates the presence of an alarm. On: indicates the presence of an alarm
O : indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
FUMES FAILURE
Fault correlated to the  ue exhaust
motor.
The restoration operations must be carried out by an
authorised technician.
FUMES PROBE
Fault correlated to the fumes probe. The restoration operations must be carried out by an
authorised technician.
FUMES OVERTEM
PERATURE ALARM
The  ue gas temperature has exceeded
310°C
Check pellet  ow (see Pellet feed adjustment”).
Check that the machine is clean, including the  ue route.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an
authorised technician.
NO FLOW ALARM
The door is not closed correctly.
The ash drawer is not closed correctly.
The depression sensor is faulty.
The combustion chamber is dirty.
The  ue exhaust pipe is blocked.
Incorrect installation
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Other restoration operations must be carried out by an
authorised technician.
DEPR ALARM
the mechanical depression sensor has
tripped:
contact after-sales centre
NO
IGNITION
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
Check for the presence of pellets in the feed-box.
Adjust pellet  ow (see Pellet feed adjustment”).
Check the procedures described in the Ignition chapter.
Other restoration operations must be carried out by an
authorised technician.
BLACKOUT NO
IGN.
No current during the ignition phase. Take the stove to OFF conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
Other restoration operations must be carried out by an
authorised technician.
NO PELLETS
In the work phase, the t° of the  ue
gases has dropped below factory
parameters
Check for the presence of pellets in the feed-box.
Regulate the pellet  ow.
Other restoration operations must be carried out by an
authorised technician.
COOLING
STANDBY
Attempt to release the alarm with stove
still in cooling mode.
Every time the stove displays one of the alarms listed above it will
switch-o automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and STANDBY alternately on the display.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
DEBIMETER
FAULTY
component disconnected or faulty Contact after-sales assistance