EasyManua.ls Logo

Extron electronics ShareLink Pro 500 - Page 45

Extron electronics ShareLink Pro 500
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ShareLink Pro 500 • SIS Configuration and Control 38
Command ASCII Command
(Host to Device)
Response
(Device to Host)
Additional Description
Access modes
Set access mode
EM X4@SHAR} SharM X4@*X4#]
View access mode
EMSHAR} X4@*X4#]
SharM X4@*X4#]
(Verbose mode 2/3)
Set confirmation-code mode
EM X4$PINC} PincM X4$]
View confirmation-code
mode
EMPINC} X4$]
PincM X4$]
(Verbose mode 2/3)
Set fixed login key code
EV X4%PINC} PincV
X4%]
View current login key code
EVPINC} X4%]
PincV
X4%]
(Verbose mode 2/3)
Set random code interval
EIX4^PINC} PincIX4^]
View random code interval
EIPINC} X4^]
PincIX4^]
(Verbose mode 2/3)
Set WebView password
option
EM X4&WBSH} WbshM X4&]
View WebView password
option
EMWBSH} X4&]
WbshM X4&]
(Verbose mode 2/3)
Set WebView password
EP<password>WBSH} WbshP]
Set WebView password
back to default
EP
WBSH} WbshP****]
Default = WebView
View WebView password
EPWBSH} ****]
]
WbshP****]
If password is not set to default
If password is set to default
(Verbose mode 2/3)
Set password
EPSWD*<username>}
<current password>}
<new password>}
<new password>}
Pswd*<username>]
NOTES:
The PSWD command must use the carriage return character (hex 0D) and not the pipe character (|) as
delimiters. This allows the pipe character to be part of a password, if desired.
Password can be up to 128 characters. All human-readable characters are permitted. The password
cannot be a single space. Passwords are case-sensitive.
The PSWD command will return E35 if the account <username> does not exist.
KEY:
X4@ = Access mode
1 = Full control 2 = Moderated 3 = Run-time (default)
X4# = Run time access mode
1 = Full control 2 = Moderated
X4$ = Confirmation code mode
0 = None 1 = Fixed 2 = Random (default)
X4% = Login key code
Four digit value (default = 0000)
X4^ = Random code interval
Four digit value (1 to 9998) in minutes
Default = 9999 = random code generated after every collaboration session
(after the last user disconnects)
X4& = WebView password option
0 = No access (disabled) 1 = No prompt for password (default)
2 = Custom password 3 = Follow confirmation code