E145S 10 532369 - Rev.A
Translation of the original instructions
ENGLISH
29 EDGE2
(Safety in closing devices active)
Connect a sensitive edge that, when activated during
closing, causes the gate to reverse.
This input can be configured by setting programming
function Sc to connect:
• sensitive edges with NC contact -default-
• resistive sensitive edges 8.2 k
i
If the input is not used, bridge it with the
common contacts (-).
LIMIT SWITCHES
J6
LOCKMAIN
LAMP
M1 M2 IN1 IN2 IN3 IN4 IN5
F+/R1 -/R2
M M
230V~
60W max
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
COM
OP
CL
PE
N
L
COM
OP-A
+24V
+24V
-
-
-
-
OP-B
STOP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1
LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
If no limit switches are used, there is no need to bridge
the inputs (NC). If at least one limit switch is used,
any unused contacts must be bridged with the com-
mon contacts (-).
23 FCA1 Opening limit switch motor 1 (NC)
24 FCC1 Closing limit switch motor 1 (NC)
25 FCA2 Opening limit switch motor 2 (NC)
26 FCC2 Closing limit switch motor 2 (NC)
To configure connections and functions, see § Ac-
cessories.
BUS 2EASY DEVICES
LOCKMAIN
LAMP
M1 M2 IN1 IN2 IN3 IN4 IN5
F+/R1 -/R2
M M
230V~
60W max
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
COM
OP
CL
PE
N
L
COM
OP-A
+24V
+24V
-
-
-
-
OP-B
STOP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1
LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C C
J10
i
If no BUS 2easy devices are used, leave the terminals
free.
For connecting and assigning addresses see § Ac-
cessories.
Do not exceed the maximum load of 500 mA.
ACCESSORIES POWER SUPPLY
J3
IN1 IN2 IN3 IN4 IN5
F+/R1 -/R2
M M
230V~
60W max
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19
20 21 22 27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
OP-A
+24V
+24V
-
-
-
OP-B
STOP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1
LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C C
500 mA max
The E145S supplies 24 V
"
and is short-circuit pro-
tected with a maximum current of 500 mA for con-
nected accessories.
14…16
-
Common contacts / Accessories power supply
negative
17 , 18 +24V Accessories power supply positive
OUTPUTS
LOCK
MAIN
LAMP
M1 M2 IN1 IN2 IN3 IN4 IN5
F+/R1 -/R2
M M
230V~
60W max
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
18 19 20 21 22
27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
+24V
+24V
-
-
-
-
OP-B
STOP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1
LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C C
J3
J12
100 mA max
The E145S has two Open Collector outputs that are ac-
tivated according to programming functions o1 and o2.
OUT active OUT not active
0 V
"
open circuit
Do not exceed the maximum load of 100 mA for each
output.