E145S 25 532369 - Rev.A
Translation of the original instructions
ENGLISH
BUS 2EASY CONTROL DEVICES
!
Do not use the BUS 2easy line for emergency stop
commands.
1. Configure the DIP switches on the device to assign
1 o 2 commands.
i
Stop NC also generates a stop when the device is
disconnected. A command (e.g.: OPEN A_1) must be
used on only one of the connected devices.
2. Register the device (see specific section).
3. Check the BUS 2easy devices (see specific section)
and make sure that the automation operates ac-
cording to the type of control devices installed.
7 Addressing Control Devices
Key: 0=OFF , 1=ON
DIP switch 5 enables the device for 1 (OFF )command or 2 (ON)
commands
0 0 0 0 0
Open A_1
0 0 0 0 1
Open A_1 Open B_1
0 0 0 1 0
Open A_2
0 0 0 1 1
Open A_1 Open B_2
0 0 1 0 0
Open A_3
0 0 1 0 1
Open A_1 Stop
0 0 1 1 0
Open A_4
0 0 1 1 1
Open A_1 Close
0 1 0 0 0
Open A_5
0 1 0 0 1
Open A_2 Open B_1
0 1 0 1 0
Stop
0 1 0 1 1
Open A_2 Open B_2
0 1 1 0 0
Stop NC_1
0 1 1 0 1
Open A_2 Stop
0 1 1 1 0
Stop NC_2
0 1 1 1 1
Open A_2 Close
1 0 0 0 0
Close
1 0 0 0 1
Open A_3 Open B_3
1 0 0 1 0
Open B_1
1 0 0 1 1
Open A_3 Open B_4
1 0 1 0 0
Open B_2
1 0 1 0 1
Open A_3 StopNC_1
1 0 1 1 0
Open B_3
1 0 1 1 1
Open A_3 Close
1 1 0 0 0
Open B_4
1 1 0 0 1
Open A_4 Open B_3
1 1 0 1 0
Open B_5
1 1 0 1 1
Open A_4 Open B_4
1 1 1 0 0
/
1 1 1 0 1
Open A_4 StopNC_2*
1 1 1 1 0
/
1 1 1 1 1
Open A_4 Close
ON
1 2 3 4 5
ON
1 2 3 4 5
BUS 2EASY STATUS
To verify the BUS 2easy connection, check the 2EASY
LEDs on the board:
BUS MON
At least one device is in operation
NO devices in operation
BUS
OK
SLEEPING
SHORT CIRCUIT
ERROR
The status of the BUS 2easy is also shown in the
bu
function in Basic Programming:
no
No device registered
-
At least one device registered
cc
BUS 2easy line short-circuited
Er
BUS 2easyline error
BUS 2EASY DEVICE REGISTRATION
Registration is required:
- when the automation system is first started or after
the board has been replaced
- following any changes (addition, replacement or
removal) to the BUS 2easy devices
Registration procedure:
The SETUP procedure registers the BUS 2easy devices
that are connected. Alternatively, you can carry out
the following procedure.
1. With the board powered, go to the
bu function
in basic programming. If there are no devices
registered,
no will appear on the display, otherwise
segment 13 will be lit (6).
Press the ++ and
--
simultaneously for at least 5 s.
The display flashes, then
Y appears (registration
complete).
2. Release the buttons.
3. Exiting from programming mode.

Table of Contents