E145S 17 532369 - Rev.A
Translation of the original instructions
ENGLISH
Function default
nc
THOUSANDS OF CYCLES
Displays the thousands of cycles that have been
performed.
To reset the cycle counter: press
++ and
--
for 5 s
0065 (programmable if AS = Y)
00
nd
TENS OF CYCLES
Displays the tens of cycles that have been per-
formed.
0053 (if AS = no)
0065 (programmable if AS = Y)
00
St
LEAVING THE PROGRAMMING MODE
Y exit saving the settings
no exit without saving the settings
After having confirmed using button
FF, the display
indicates the STATUS of the automation:
Y
00 CLOSED 08 CHECK Bus 2easy
01 OPEN
09 PREFLASHING BEFORE OPEN-
ING
02 STATIONARY THEN OPENS
10 PREFLASHING BEFORE CLOS-
ING
03 STATIONARY THEN CLOSES 11 EMERGENCY OPEN
04 IN PAUSE 12 EMERGENCY CLOSE
05 OPENING HP HOLD POSITION
06 CLOSING . (flashing) SLEEP
07 FAILSAFE IN PROGRESS
6.3 OPERATING LOGICS
i
the STOP command has priority in all the logics and
stops the automation.
The CLOSE command always closes the automation.
E SEMI-AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the photocells: during movement,
reverses the gate.
EP SEMI-AUTOMATIC STEP-BY-STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening or closing, stops the gate and
the next OPEN command reverses the direction.
The triggering of the photocells: during movement,
reverses the gate.
S AUTOMATIC SAFETY
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during opening, causes it to close.
OPEN during pause, causes it to close.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to reverse
and then closes it immediately.
SA AUTOMATIC SAFETY 2
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during opening, is ignored.
OPEN during pause, causes it to close.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.
SP AUTOMATIC STEP BY STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.