9. UPLOAD/DOWNLOAD
There is a USB port on the E145S board that can be used
for the following:
- Load data from a USB pen drive (UPLOAD)
- saving data to a USB pen drive (DOWNLOAD).
i
Use a USB storage device that has a maximum power
consumption of 500 mA formatted with the FAT or
FAT 32 file system. The NTFS format is not recognised
by the board.
1. Turn the power off and insert the USB pen drive
into the USB port on the Logic board and then
switch on the board.
2. bo appears on the display and the USB LED comes
on.
3. Press and release the
FF button to scroll through
the Upload/Download menu options (see rela-
tive table).
UPLOAD OPERATIONS
i
In order to be used, the files must be saved in the
root directory of a USB memory device (not in a
folder or a zip file and without their original names
being changed).
Display Function File name
US
Update FW E145Ssw.cod
Uc
Upload board configuration E145.prg
Ut
Not used
Ur
Upload radio codes E145.rad
1. Press and hold the
++ and
buttons simultane-
ously for at least 5 seconds in order to carry out
the function displayed.
- the update starts:
--flashes on the display and the
USB LED flashes. Release the buttons.
- The procedure ends when
Y appears on the display.
If there are errors
no appears on the display and the
red ERROR LED lights up. To display the error code,
press buttons
++ and
simultaneously. The error
messages are described in the Diagnostics Section.
2. Press
FF to return to the menu.
DOWNLOAD OPERATIONS
Display Function File name
dC
Download board configuration E145.prg
dt
Not used
dr
Download radio codes E145.rad
1. To carry out the function displayed, press and hold
the
++ and
buttons simultaneously for at least 5
seconds, until
00 appears on the display.
2. Release the buttons and use the
++ or
buttons
to select the method for saving the file to the root
of the USB storage device:
00
saves the file without a suffix and overwrites
any existing file with the same name in the USB
memory (e.g. E145.prg)
01
saves the file by adding a 3-digit suffix to
the name (e.g. E145000.prg) and if there is
already a file with the same name in the root
of the USB memory, the number of the suffix
is incremented.
Note: the suffix must be deleted if you wish to
load the file in the upload operation.
3. Press
FF to run.
The procedure ends when
Y appears on the display.
If there are errors
no appears on the display and the
red ERROR LED lights up. To display the error code,
press buttons
++ and
simultaneously. The error
messages are described in the Diagnostics Section.
4. Press
FF to return to the menu.